Chapter 3 Installing the TimeSource 3100
Powering Up the Shelf
78 TimeSource 3100 User’s Guide 097-72020-01 Revision K – December 2005
COMPRI=e Sets the communication port capabilities as follows:
ALW0 = normal communication, no autonomous messages
ALW1 = normal communication, autonomous messages
ALW2 = autonomous messages received, logged on or not
INH = closes connection and keeps port from use (command must go to
another port) (if the port is in use, this command also logs off the user)
AUTOLOGOFF=c Inactive minutes until the unit logs off the user, keeping the
connection open (c = 0 to 255)
SWCONTROL=b uses software (XON/XOFF) flow control (b=ALW), or no flow
control (b=INH)
27.If you are not using an Element Manager, skip to Step 29. If you are not using a
separate port to send autonomous messages to an Element Manager, skip to
Step 28.
Use the Edit Equipment command to set the IP address and port address of the
Element Manager. Port 5550 connects to this address when the TimeSource
3100 develops a TL1 autonomous message, sends any messages, and closes
the connection. An alternate Element Manager may be set up in case port 5550
cannot make a connection to the primary Element Manager.
ED-EQPT::TS3100:<ctag>:::IPEM1=a,IPEM1PORT=b[,IPEM2=a]
[,IPEM2PORT=b][,IPINACT=c];
where:
IPEM1=a Primary Element Manager's IP address in the form a.a.a.a (each a
is an independent value of 0 to 255)
IPEM1PORT=b Primary Element Manager's Ethernet port address (b = 0 to
65535)
IPEM2=a Alternate Element Manager's IP address in the form a.a.a.a (each
a is an independent value of 0 to 255)
IPEM2PORT=b Alternate Element Manager's Ethernet port address (b = 0 to
65535)
IPINACT=c Disconnects from the Element Manager if an autonomous
message is not developed during this number of 100-ms units of inactivity (0 to
10 000, where 0 deactivates the timer)
28.An Element Manager connects to port 5551 for TL1 command and response
messages. The following values for port 5551 are set at the factory and appear at
reset:
COMPRI=ALW1 (normal communication, including autonomous messages)
MONMSG=INH (monitors only the current port for messages)
KEEPALIVE=0 (does not send a COMPLD message to keep connection open)
ENDOFTEXT=0 (does not include an end-of- text code with a TL1 message)
ECHO=b Echoes characters so they appear on the user’s screen as typed
(b=ALW) or inhibits echo (b=INH)
AUTOLOGOFF=20 (does not log off the user during inactivity)
SWCONTROL=INH (uses no flow control)

Table of Contents

Other manuals for Symmetricom TimeSource 3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeSource 3100 and is the answer not in the manual?

Symmetricom TimeSource 3100 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeSource 3100
CategoryGPS
LanguageEnglish

Related product manuals