126 WEB Interface
CP560 DVB-T2 Gateway User’s Manual Rev. 2.2 (3686) ID: um_t2gateway
Note: Leap seconds are entered in UTC+00 time format. To get the
actual time of day this will be added for your local time you need to
subtract your time zone.
Leap Second Status
Status field for the leap second handling. Will state the number of days, hours, minutes
and seconds until the configured leap second will be added.
Note: An notification will be given when the leap seconds is added. This
notification can be seen in the alarm log, see section 8.3.2.
8.6.4.3 PLP configuration
The PLP configuration page has all the PLP configuration parameters. The list on the left hand
side shows the current number of PLPs in the system. It is possible to have from 1 up to the
licenced number of PLPs.
Figure 8.71 PLP Config
PLPs Common Config lists configuration parameters that apply to all the PLPs.
Override Capacity validation
This option lets you have less cell occupancy than 50% in a T2-Frame. This is not a valid
signal, and is only intended for PLP Replacement systems.