EasyManua.ls Logo

T-VIPS CP560 - 11.2.3 Fan(s) not working; unit overheating

T-VIPS CP560
200 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
160
CP560 DVB-T2 Gateway User’s Manual Rev. 2.2 (3686) ID: um_t2gateway
11.2.3 Fan(s) not working / unit overheating
This equipment has forced air cooling and must not be operated unless all cooling fans are
working. In the event of overheating problems, refer to the sequence below.
Caution: Failure to ensure a free air flow around the unit may cause
overheating.
Fan fault-finding
1. Check fan rotation.
Inspect the fans located at the sides of the unit. Are the fans rotating?
Yes
Check that the unit has been installed with sufficient space allowed enclosure
for air flow. If the air is too hot, additional cooling may be required
No
Possible break in the DC supply from the PSU module to the suspect fan(s).
Call a Service Engineer.
11.3 Disposing of this equipment
Dispose of this equipment safely at the end of its life time. Local codes and/or environmental
restrictions may affect its disposal. Regulations, policies and/or environmental restrictions differ
throughout the world; please contact your local jurisdiction or local authority for specific advice
on disposal.
11.4 Returning the unit
Before shipping the CP560 to T-VIPS, contact your local T-VIPS reseller or T-VIPS directly for
additional advice.
1. Write the following information on a tag and attach it to the CP560.
Name and address of the owner
Model number
Serial number
Description of service required or failure indication.
2. Package the CP560.
The original shipping containers or other adequate packing containers must be be
used.
3. Seal the shipping container securely, and mark it FRAGILE.

Table of Contents