Alarms 197
ID: um_t2gateway CP560 DVB-T2 Gateway User’s Manual Rev. 2.2 (3686)
Table G.3.g Alarms
Alarm ID
Text Def. severity Details
1510 Output overflow Critical
Description: The total bit rate of the ASI input stream is too high.
Type: Port (Typ e ID = 9)
Clear event: Yes
Subid2: Port identifier
1542 MIP size error Warning
Description: There is not enough space in the MIP packet for all configured transmitter
function loops.
Type: Port (Typ e ID = 9)
Clear event: Yes
Subid2: Port identifier
1543 MIP Inserter time reference problem Warning
Description: MIP Inserter time reference problem.
Type: Port (Typ e ID = 9)
Clear event: Yes
Subid2: Port identifier
1544 ETR 290 Pri 2 error Warning
Description: Setting Transport Error Indicator in PAT to trigger ETR290 Pri 2 error.
Type: Port (Typ e ID = 9)
Clear event: Yes
Subid2: Port identifier
1545 Empty PLP Warning
Description: PLP is not receiving data. Empty PLP being output.
Type: Port (Typ e ID = 9)
Clear event: Yes
Subid2: Port identifier
Subid3: Idx
1801 TS-ID incorrect Filtered
Description: The TS-ID of the incoming stream does not match the TS-ID of the
configured CSI section. For modes where the input TS-ID is not known, the
TS-ID expected must be configured manually.
Type: Port (Typ e ID = 9)
Clear event: Yes
Subid2: Port identifier
1802 PID rate too high Filtered
Description: PID bitrate is higher than set limit.
Type: Port (Typ e ID = 9)
Clear event: Yes
Subid2: Port identifier
Subid3: PID
1803 PID rate too low Filtered
Description: PID bitrate is lower than set limit.
Type: Port (Typ e ID = 9)
Clear event: Yes
Subid2: Port identifier
Subid3: PID
1812 TS rate too high Filtered
Description: TS bitrate is higher than set limit.
Type: Port (Typ e ID = 9)
Clear event: Yes
Subid2: Port identifier