AGL7 module adjustment procedures
12. Select the DAC G
ain (700 mV DC) calibration signal for BLACK 1 through
BLACK 3 as follows:
a. Press the left
()orright() arrow button to select BLACK 1,andthen
press the ENTER button.
b. Press the le
ft ()orright() arrow button to select CAL, and then press
the ENTER button.
c. Press the le
ft ()orright() arrow button to select DAC Gain (700mV
DC), and then press the ENTER button.
d. Press the B
ACK button twice to return the AGL7 main menu.
e. Repeat parts a through d of this step to select the calibration s ignal for
BLACK 2. B
LACK 3 u ses the previous setting (same as BLACK 2).
13. Locate variable resistor R681 on the AGL7 circuit board. (See Figure 4-1.)
14. Adjust R681 so that the output gain is 700 mV ±1 mV.
15. Move the BNC cable from the BLACK 1 connector to the BLACK 2
connector on the AGL7 Genlock module.
16. Locate variable resistor R481 on the AGL7 circuit board. (See Figure 4-1.)
17. Adjust R481 so that the output gain is 700 mV ±1 mV.
18. Move the BNC cable from the BLACK 2 connector to the BLACK 3
connector on the AGL7 Genlock module.
19. Locate variable resistor R581 on the AGL7 circuit board. (See Figure 4-1.)
20. Adj
ust R581 so that the output gain is 700 mV ±1 mV.
4–6 TG8000 Multiformat Test Signal Generator Service Manual

Table of Contents

Other manuals for Tektronix TG8000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TG8000 and is the answer not in the manual?

Tektronix TG8000 Specifications

General IconGeneral
BrandTektronix
ModelTG8000
CategoryPortable Generator
LanguageEnglish

Related product manuals