Log item name Unit Description
PR_reset_6hour_sum:PR_Curr
mm Resetting sum of rainfall from the previous
6 hours
1)
PR_reset_12hour_sum:PR_Curr
mm Resetting sum of rainfall from the previous
12 hours
1)
PR_reset_24hour_sum:PR_Curr
mm Resetting sum of rainfall from the previous
24 hours
1)
Lightning_Selector:TOTAL
– Total number of flashes from the lightning
sensor
SR_Wm2_1min_avg:Avg
W/m
2
1‑minute average solar radiation
SunShineCalc:SS
– Sunshine status:
• 1 = The sun is shining
• 0 = The sun is not shining
SunShine24h:Sum_Last
min
Sunshine duration from the previous 24 hours
2)
Watt_m2_ToJoule_cm2:value
J/cm
2
Radiant exposure. Sliding sum calculated from
the previous 24 hours.
Watt_m2_ToJoule_cm2_PrevDay:value
J/cm
2
Radiant exposure. Resetting sum from the
previous 24 hours.
2)
TS1_1min_avg:Avg
°C 1‑minute average soil temperature
TS2_1min_avg:Avg
°C 1‑minute average soil temperature from the
second soil temperature sensor
TR_1min_avg:Avg
°C 1‑minute average runway temperature
Charger:External_DC
V Voltage measurement from QML201C supply
DC voltage
BatteryVoltage:meas
V Voltage measurement of the battery
INT_PT100:T_int
°C Internal Pt100 temperature measurement
DoorStatus:status
– Status of enclosure door:
• 1 = Door is open
• 0 = Door is closed
BatteryLow:status
– Status of battery low alarm:
• 1 = Battery voltage is below threshold
• 0 = Battery voltage is at correct range
MainsOnOff:status
– Status of AC (mains) power supply. The status
is measured from DC power supply input.
• 1 = Mains power supply is o
• 0 = Mains power supply is on
InternalTemp:status
– Status of internal temperature alarm:
• 1 = Measured internal temperature is above
accepted limit
• 0 = Internal temperature is at correct range
AWS310-SITE Configuration and Maintenance Manual M211828EN-C
154