Log item name Unit Description
SolarRadiationStatus:status
– Status of solar radiation measurement:
• 1 = Measured solar radiation is out of range
• 0 = No alarm
TempRunwayStatus:status
– Status of runway temperature measurement:
• 1 = There is a problem in runway
temperature measurement port or sensor
cable
• 0 = No alarm
TempSoilStatus:status
– Status of soil temperature measurement:
• 1 = There is a problem in soil temperature
measurement port or sensor cable
• 0 = No alarm
TempSoilStatus2:status
– Status of second soil temperature
measurement:
• 1 = There is a problem in second soil
temperature measurement port or sensor
cable
• 0 = No alarm
PTB330:err
– Error flags of PTB330
PTB330:status
– Status of PTB330
MessageDispatcher:Gen_HW_alarm
– General hardware alarm:
• 1 = Alarm is active
• 0 = No alarm
TA_Selector:sensor_status
– Status of dry bulb temperature measurement
RH_Selector:sensor_status
– Status of relative humidity measurement
RHStatus:status
– Boolean status of relative humidity
measurement
• 1 = Error in temperature measurement
• 0 = No error
TAStatus:status
– Boolean status of dry-bulb temperature
measurement
• 1 = Error in temperature measurement
• 0 = No error
Lightning_Selector:status
– Status of TSS928
1) The sum is reset every time the period starts over and the resetting is synched to 6 a.m. local time.
2) The sum is reset at 6 a.m. local time.