EC-Declaration of Conformity
Note: This Declaration of Conformity and the -mark affixed to the nameplate are valid for the vacuum pump within the Busch-scope of delivery.
When this vacuum pump is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating
company, too) must conduct the conformity assessment process acc. to the Directive Machinery 2006/42/EC for the superordinate machine, issue
the Declaration of Conformity for it and affix the -mark.
We
Busch Produktions GmbH
Schauinslandstr. 1
79689 Maulburg
Germany
declare that vacuum pumps KC 0016 D VEMAG
in accordance with the European Directives:
–
“Machinery” 2006/42/EC,
–
“Electrical Equipment Designed for Use within Certain Voltage Limits” (so called “Low Voltage”) 2006/95/EC,
–
“Electromagnetic Compatibility” 2004/108/EC,
have been designed and manufactured to the following specifications:
Standard Title of the Standard
Harmonised Standards
EN ISO 12100-1
EN ISO 12100-2
Safety of machinery - Basic concepts, general principles of design - Part 1 and 2
EN ISO 13857 Safety of machinery - Safety distances to prevent hazard zones being reached by the upper and lower limbs
EN 1012-1
EN 1012-2
Compressors and vacuum pumps - Safety requirements - Part 1 and 2
EN ISO 2151 Acoustics - Noise test code for compressors and vacuum pumps - Engineering method (grade 2)
EN 60204-1 Safety of machinery - Electrical equipment of machines - Part 1: General requirements
EN 61000-6-1
EN 61000-6-2
Electromagnetic compatibility (EMC) - Generic immunity standards
EN 61000-6-3
EN 61000-6-4
Electromagnetic compatibility (EMC) - Generic emission standards
Manufacturer Person authorised to compile
the technical file
Dr.-Ing. Karl Busch
General director
Andrej Riwe
Technical writer
Troubleshooting
WARNING_ab
Risk of electrical shock, risk of damage to equipment.
Electrical installation work must only be executed by qualified personnel that knows and observes the following regulations:
- IEC 364 or CENELEC HD 384 or DIN VDE 0100, respectively,
- IEC-Report 664 or DIN VDE 0110,
- BGV A2 (VBG 4) or equivalent national accident prevention regulation.
CAUTION_ac
During operation the surface of the vacuum pump may reach temperatures of more than 70 °C.
Risk of burns!
Let the vacuum pump cool down prior to a required contact or wear heat protection gloves.
KC 0016 D VEMAG
Troubleshooting
0870146800 / 100111 page 3