HP10E / HP12E / HP15E / HP20E - Dairy design 6. Graphical control
6-25© VEMAG 2013
6.6.3 Basic parameters
The basic parameters are displayed on the left-hand side of the
screen. These parameters are required for the majority of applications.
The parameters cannot be scrolled.
Supplementary parameters for various applications (e.g. working with
a clipper) are explained in the sections which follow.
6.6.3.1 Weight
Display: Weight
Unit: Gramme [g]
Resolution: 0.1 g/1 g
Setting range: 1 – 99,999 g
Application: All applications (not for mode group "Fill")
Enter a new weight
• Enter a new weight.
• Press Enter.
Correct weight
• Enter correction value with symbol in front.
• Press Enter.
From a lling weight of 1,000 g, resolution automatically switches from
0.1 g to 1 g.
A weight correction can only be made up to a maximum of 90 % of the
specied weight. Otherwise the message "Input limit reached" appears.