HP10E / HP12E / HP15E / HP20E - Dairy design 4. Setting up
4-3© VEMAG 2013
4.3 Fitting the double screws
• Inspect the double screws for residual product prior to assembly.
• Bring the slots of coupling claws (1) into the correct position in relation
to the coupling pins in the feed cylinder by turning the double screws
(2) in opposite directions.
1 Slots
2 Double screws
Fig. 4-3
Lining up the double
screws
2
1
• Push double screws (1) into double screw housing (2) up to the stop.
The double screws are properly engaged if the end faces of the dou-
ble screws and housing are ush.
1 Double screws
2 Double screw housing
Fig. 4-4
Installation of double
screws
1