Number Message Cause Remedy
300 IO modules ready The IO modules are ready. -
301 Voltage IO module A4 No voltage at module A4. Check voltage at module A4.
302 IO module A4 IO module A4 is not present or not
functioning properly.
Check that module A4 is rmly
seated; replace the module if
necessary.
311 Voltage IO module A5 No voltage at module A5. Check voltage at module A5.
312 IO module A5 IO module A5 is not present or not
functioning properly.
Check that module A5 is rmly
seated; replace the module if
necessary.
320 DIAS communication A1
<-> A3
Communication between A1 (PC)
and module A3 (CIC) is defective.
Check the line and the shielding;
replace the module or the PC if
necessary.
321 CIC module A3 Communication module A3 (CIC)
is not present or not functioning
properly.
Check the module power supply
and the DIAS line.
322 Oil leak detected in feed
system drive
The feed system drive has an oil
leak (Dairy).
Eliminate the oil leak.
350 F5: vacuum pump/eleva-
tor/transformer
Monitoring module F5 has found
overheating at the vacuum pump,
hoist unit or power transformer.
Allow the machine to cool down.
Check the vacuum pump and hoist
motors.
351 Voltage F+24V fuse F4 No voltage at F+24V. Check voltage F+24V and fuse F4.
353 Unexpected signal X3:2
(F6-S2)
Change of status at digital input
A4 X3:2 (F6-S2) without matching
signal at A4 X6.1 (V+24 V).
Check the wiring from A4 to F6.
354 Unexpected signal X3:2
remote-E
Change of status at digital input
X3:2 (remote-E) from module A5
during production.
Check service page 3. Check the
contacts between the remote con-
trol connector and socket.
355 Unexpected signal X2:4
(F6-S4)
Change of status at digital input
A6 X2:4 (F6-S4) without matching
signal at A4 X6.1 (V+24 V).
Check the wiring at A6 to F6.
360 Oil level vacuum pump The oil level in the vacuum pump
is too low.
Replenish oil if necessary.
362 Sensor under pressure or
defective!
Zero adjustment of pressure
sensor failed.
Clear the sensor for zero adjustment.
Check the sensor and its wiring;
replace the sensor if necessary.
363 IO module A7 IO module A7 is not present or not
functioning properly.
Check that module A7 is rmly
seated; replace the module if
necessary.