HP10E / HP12E / HP15E / HP20E - Dairy design6. Graphical control
6-36 © VEMAG 2013
Working with sausage lines
6.6.4.13 Product type
Display: Product type
Selection: Cooked sausage / Fresh sausage
Application: LPG 208, LPG 209
• Enter product type
• Press Enter.
6.6.4.14 Last portion
Display: Last portion
Unit: Per cent [%]
Resolution: 0.1 %
Setting range: 1 – 100 % / 0 = Off
Application: LPG 208, LPG 209
• Enter value in per cent up to which the last portion is to be lled.
• Press Enter.
6.6.4.15 Split casing tolerance
Display: Burst tolerance
Selection: Off/Value
Unit: Value
Resolution: 1
Setting range: 2 – 12
Application: LPG 208, LPG 209 with TM 203
• Enter value up to which defective link points / split casings are to be
tolerated.
• Press Enter.
The higher the value set, the less sensitively the machine reacts.
Example:
setting = 12, i.e. machine only stops after 12 faulty links (split casings).