HP10E / HP12E / HP15E / HP20E - Dairy design 4. Setting up
4-5© VEMAG 2013
4.5 Setting the vacuum
4.5.1 Filling liquid products
• Set the vacuum down for lling liquid products.
Warning!
Before processing any liquid product, check whether the vacuum has
been set down. If the vacuum is not correct, the vacuum pump may
be destroyed. If the vacuum pump takes in product or water as a con-
sequence of the vacuum not correctly set, it is essential to proceed as
follows to prevent damage to or destruction of the vacuum pump:
• Stop the machine immediately.
• Clean the air lter in the intake line.
• Change the oil in the vacuum pump.
Section 8 and vacuum pump operating instructions