HP10E / HP12E / HP15E / HP20E - Dairy design 6. Graphical control
6-29© VEMAG 2013
6.6.3.7 Individual speed
Display: Individual speed
Unit: Per cent [%]
Resolution: 0,1 %
Setting range: 25.0 – 75.0 %
Application: Double outlet
• Enter speed.
• Press Enter.
If only one outlet of a double outlet is operated, you can set the speed
for this outlet. The speed percentage for this outlet is displayed in the
„Speed“ parameter (small grey number in the display).
6.6.3.8 Back suction
Display: Back suction
Selection: On / Off
Unit: Gramme [g]
Resolution: 0.1 g
Setting range: 0 – 200 g (0 - 120 g for DP machines)
Application: When switched on, back suction prevents the product
running on once a portion has ended.
• Enter back suction quantity. Entering "0" switches off the parameter.
• Press Enter.
Machines which are not equipped with the standard lling horn holder
but have a larger machine outlet may not perform back suction for safety
reasons. In this case, back suction is blocked. The back suction quantity
may not exceed the specied weight dened in weight (does not apply to
“LPG” mode).
6.6.3.9 LPG belt speed
Display: LPG belt speed
Unit: Per cent [%]
Resolution: 1 %
Setting range: 0 – 100 %
Application: Speed of the dividing belts of the LPG
• Enter belt speed.
• Press Enter.
Belt speed can be limited by lling rate and number of links.