EasyManua.ls Logo

VEMAG HP12E - 7. Cleaning; 7.1 General information; 7.2 Removing parts to be cleaned; 7.2.1 Filling horn holder

Default Icon
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HP10E / HP12E / HP15E / HP20E - Dairy design 7. Cleaning
7-1© VEMAG 2013
7. Cleaning
7.1 General information
The machine and any attachments and additional devices (optional) must
be cleaned daily.
Danger!
To prevent injury, take the following measures before cleaning.
Press the OFF key on the machine control panel.
Switch off the main switch of the machine to disconnect it from the
mains.
Disconnect any attachments or additional devices (optional) from the
mains and remove the devices
Attachment operating instructions
7.2 Removing parts to be cleaned
7.2.1 Filling horn holder
Undo lling horn nut and remove attachment (optional), if present.
Undo the locking nut (1) with the handle anticlockwise until the bayo-
net lugs come free and remove the lling horn holder (2). The lling
horn holder can be washed either manually, in a cleaning tank, or
dishwasher.
1 Locking nut
2 Filling horn holder
Fig. 7-1
Removing the lling horn
holder
1
2
After cleaning, the lling horn holder should be inspected for any resi-
dual product. Following this, it may be sanitized manually or mechani-
cally with an EPA accepted sanitizing agent.