EasyManua.ls Logo

VEMAG HP12E - Group Portions; Group Pause

Default Icon
167 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HP10E / HP12E / HP15E / HP20E - Dairy design 6. Graphical control
6-49© VEMAG 2013
6.6.4.45 Group portions
Display: Group portion
Unit: Number of portions/gramme g
Resolution: 1/0.1 g
Setting range: 0 - 99/0.1 g - 60,000.0 g
Application: Forming machine FM 250 (kebab production)
Enter the number of portions (e.g. kebab slices) of identical weight.
Enter weight.
Press Enter.
Here you dene how many portions of identical weight you want
to produce and determine the weight of these portions.
Example: 1. 5 x 300 [g]
The rst portion has a weight of 300 g and is produced
a total of ve times.
You can enter up to 25 group portions. If the last portion of a frame (e.g.
No. 5) is > 0, the next frame is displayed (No. 6 - 10).
6.6.4.46 Group pause
Display: Group pause
Unit: Milliseconds [ms]
Resolution: 1 ms
Setting range: 0 – 9,999 ms (-1 = off)
Application: Forming machine FM 250 (kebab production)
Enter group pause.
Press Enter.
Here you dene the pause after which all group portions are produced
(e.g. set-up time for changing stick when making kebabs). The group
pause can only be larger than the value set under "Pause". If the group
pause has been switched off, the value set under "Pause" also applies
between groups.

Table of Contents

Related product manuals