HP10E / HP12E / HP15E / HP20E - Dairy design 6. Graphical control
6-55© VEMAG 2013
6.6.4.58 Maximum temperature (temperature monitoring for the grinding system)
Display: Temperature
Unit: Degrees [°C] / Kilogram [kg]
Resolution: 0.1 °C / 1 kg
Setting range: Off / -19.9 °C – +31.0 °C / 1,0 kg - 99 kg
Application: Separation grinder 982, separation attachment 801
• Enter the max. temperature, at which to sound the alarm.
• Enter the min. temperature to dene a temperature range you wish to
monitor.
• Enter the lling volume still to be reached after the alarm is sounded
before the machine stops.
• Press Enter.
This function monitors temperature in separation grinder 982/ separation
attachment 801. Current temperature is displayed in degrees Celsius.
If the temperature is outside the dened range, a message is issued
and the relevant indicator comes on.
6.6.4.59 Hopper mode
Display: Hopper mode
Selection: Off / Vacuum / Cleaning / Automatic
Application: Vacuum hopper 149
• Select hopper mode.
• Press Enter.
„Off“ = Hopper vacuum off
„Vacuum“ = Hopper vacuum on
„Cleaning“ = The connecting pipe can be cleaned with pig.
„Automatic“ = The hopper levels of the vacuum and feed
hopper (optional) are monitored.
Warning!
The vacuum hopper cannot be lled if no vacuum has been applied.