HP10E / HP12E / HP15E / HP20E - Dairy design 6. Graphical control
6-51© VEMAG 2013
Working with the scale
6.6.4.49 Number of samples (VEMAG Scale 877)
Display: Number of samples
Unit: Number
Resolution: 1
Setting range: 1 – 99
Application: VEMAG scale 877
Enter the number of samples to be placed on the scale.
Press Enter.
For the check, the computer determines the weight of one portion from
this. If a new sample is expected, the corresponding information appears
in the display.
6.6.4.50 Sample interval (VEMAG Waage 877)
Display: Sample interval
Unit: Number
Resolution: 1
Setting range: 1 – 999 (0 = Automatic)
Application: VEMAG scale 877
Enter sample interval.
Press Enter.
If „0“ was selected, the control system automatically calculates the sam-
ple interval.
If the machine is stopped as there is no sample has been applied, a stop
condition can be selected:
„0“ = Off
„-1“ = The machine stops automatically at the end of the line.
„Number“ = The machine stops automatically once the selected
number of portions has been reached after the „Please
apply sample“ message.
6.6.4.51 Tendency control (e.g. Process Check)
Display: Tendency control
Selection: Off / per second / per pulse
Unit: Gramme [g]
Resolution: 0.1 g
Setting range: 0.0 – 99.9 g
Application: e.g. Process Check
Enter correction for weight.
Press Enter.
Tendency control is used to correct weight using pulses from an external
scale. Corrections may be positive or negative.