HP10E / HP12E / HP15E / HP20E - Dairy design6. Graphical control
6-34 © VEMAG 2013
6.6.4.9 Metal detection
Display: Metal detection
Selection: Off / Manual / Reject system
Unit: Gramme [g] / Milliseconds [ms] / Speed [%]
Resolution: 1 g / 1 ms / 1 %
Setting range: 1 – 2,000 g / 10 – 2,000 ms / 10 – 100 %
Application: Metal detector
Enter weight/delay time and speed.
Press Enter.
Metal detection has two functions.
1. Manual removal of the foreign body. The foreign body is rejected
at a dened weight and speed.
2. Automatic removal of the foreign body using the reject system.
The foreign body is rejected at a dened delay time and speed.
6.6.4.10 Vacuum control
Display: Vacuum control
Selection: Off / Time / Vacuum deactivated
Unit: Seconds [sec] / Milliseconds [ms]
Resolution: 0.1 sec / 1 ms / 1 ms
Setting range: 0.1 – 25.5 sec / 0 – 99,999 ms (default = 5,000) /
0 – 99,999 ms (default = 15,000)
Application: Automatic vacuum control (optional)
Enter venting time.
Press Enter.
The stop valve closes and the feed system is vented for the set time
in order to reduce the vacuum in pauses.
„0“ = Vacuum control off (= vacuum is permanently active)
„-1“ = Vacuum deactivated
Enter switch-on delay.
Press Enter.
The machine restarts following the set switch-on delay. This ensures
that the required vacuum can be built back up.
Enter switch-off delay.
Press Enter.
The machine stops, the vacuum is switched off after the set switch-off
delay and the feed system is vented.