Drive
CIMR-Jo
Filter Data (Manufacturer: Schaffner)
Type
Rated
Current
(A)
Weight
(lb)
Dimensions
[W x L x H] (in)
Mounting
Dimensions
[Y x X] (mm)
Drive
Mounting
Screw A
Filter
Mounting
Screw
400 V Three-Phase Units
4A0001 FS23639-5-07 5 1.10 4.4 x 6.7 x 1.8 3.6 x 6.1 M4 M5
4A0002 FS23639-5-07 5 1.10 4.4 x 6.7 x 1.8 3.6 x 6.1 M4 M5
4A0004 FS23639-5-07 5 1.10 4.4 x 6.7 x 1.8 3.6 x 6.1 M4 M5
4A0005 FS23639-10-07 10 1.54 4.4 x 6.7 x 1.8 3.6 x 6.1 M4 M5
4A0007 FS23639-10-07 10 1.54 4.4 x 6.7 x 1.8 3.6 x 6.1 M4 M5
4A0009 FS23639-10-07 10 1.54 4.4 x 6.7 x 1.8 3.6 x 6.1 M4 M5
4A0011 FS23639-15-07 15 1.98 5.7 x 6.9 x 2.0 4.7 x 6.3 M4 M5
H
X
L
W
Y
LINE
A
PE
LOAD
Figure D.6 EMC Filter Dimensions
n
DC Link Chokes for EN 61000-3-2 Compliance
Table D.2
DC Link Chokes for Harmonics Reduction
Drive Model
CIMR-Jo
DC Link Choke
Model Rating
200V Three-Phase Units
2A0004
UZDA-B
5.4 A
8 mH
2A0006
400 V Three-Phase Units
4A0002
UZDA-B
3.2 A
28 mH
4A0004
Note: Models not listed in the above table do not require a DC link choke for EMC compliance.