EasyManua.ls Logo

YASKAWA NX100 - Page 136

YASKAWA NX100
247 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.3 Alarm Message List
8-32
1510 EXTERNAL WDT
BREAKDOWN
(SERVO I/O)
--- External WDT breakdown is sent
from the TU circuit board.
• Turn the power OFF then back ON.
If the error occurs again, replace the TU cir-
cuit board.
1511 SERIAL COM-
MUNICATION
TOGGLE CHECK
ERROR
(SERVO I/O)
--- Serial communication toggle check
error is sent from the TU circuit
board.
• Turn the power OFF then back ON.
If the error occurs again, replace the TU cir-
cuit board.
1512 POWER SUP-
PLY FAN ALARM
(SERVO)
--- The rotation speed of in-panel cool-
ing fan decreased.
• Check if in-panel cooling fan is rotating.
If the fan is not working, verify its wiring.
Should the error persist, replace the in-panel
cooling fan (CPS power unit).
1513 POWER
SUPPLY
OVERHEAT
(SERVO)
--- Temperature sensor in the CPS
power unit is activated. The internal
temperature of the controller is
abnormally increased.
• Check for temperature rise in the controller,
and check if in-panel cooling fan is rotating.
Cycle the power when the power supply unit
is cooled off.
1514 OVERHEAT
(AMPLIFIER)
--- Amplifier overheated. • Turn the power OFF then back ON after
cooling the amplifier.
If the error occurs again, contact your
Yaskawa representative.
1515 SON_OUT
RELAY STICK-
ING
(SERVO)
--- SON_OUT relay sticking is sent
from the TU circuit board.
• Turn the power OFF then back ON.
If the error occurs again, replace the TU
board.
1516 BRRCER RELAY
STICKING
(SERVO I/O)
--- BRRCER relay sticking is sent form
the TU circuit board.
• Turn the power OFF then back ON.
If the error occurs again, replace the TU
board.
1530 ABSOLUTE
DATA
ERROR(SERVO
2)
--- Absolute data cannot be received
from the encoder or the received
absolute data is incorrect.
• Turn the power OFF then back ON.
• Correct the encoder connection.
• Replace the motor and SERVOPACK.
1531 GATE ARRAY 1
ERROR (SERVO
1)
--- Reading error of command input. • Turn the power OFF then back ON.
• Replace the SERVOPACK.
1532 GATE ARRAY 2
ERROR (SERVO
2)
--- Reading error of command input. • Turn the power OFF then back ON.
• Replace the SERVOPACK.
1533 ABSOLUTE
ENCODER
ERROR
(SERVO2)
--- The number of pulses per rotation
of the absolute encoder is incorrect.
• Turn the power OFF then back ON.
• Correct the encoder connection.
• Check for noise.
• Replace the SERVOPACK.
1534 EARTH FAULT
(SERVO2)
--- A ground fault along the motor
power line, motor error, or SERVO-
PACK error is suspected.
• Turn the power OFF then back ON.
• Check if a ground fault or interphase short-
circuiting has not occurred in the U-, V-, and
W-phases of motor power line.
• Replace the motor and SERVOPACK.
1535 WATCHDOG
DETECTOR
ERROR
(SERVO2)
--- The SERVOPACK watch dog is
incorrect.
• Turn the power OFF then back ON.
• Replace the SERVOPACK.
1536 CURRENT FB
ERROR(U
PHASE)
(SERVO2)
--- Disconnection of motor power line
or the SERVOPACK U-phase cur-
rent detection circuit error is sus-
p
ected.
• Turn the power OFF then back ON.
• Check for motor power line.
• Replace the SERVOPACK.
1537 CURRENT FB
ERROR(V
PHASE)
(SERVO2)
--- Disconnection of motor power line
or the SERVOPACK V-phase cur-
rent detection circuit error is sus-
pected.
• Turn the power OFF then back ON.
• Check for motor power line.
• Replace the SERVOPACK.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy

Table of Contents