9.1 Error Message List
9-15
9.1.5 Concurrent I/O
Error No. Data Error Message Contents
4010
Illegal relay No.
XXX Line No.
4030
Illegal instruction
XXX Line No.
4040
Relay/register No. duplicated in OUT/
GOUT or arithmetic instruction
Multiple outputs are instructed to
the relay or register.
XXX Line No.
4050
The relay is not used
XXX Line No.
4060
Excess STR-[-NOT] instructions
XXX Line No.
4070
Excess AND [OR] STR instructions
XXX Line No.
4080
Syntax error in CNT instructions
XXX Line No.
4090
Enter STR [-NOT] at head of block Need STR [-NOT]
XXX Line No.
4120 -
Concurrent I/O memory is full Exceeds memory capacity
(10000 steps)
4130 - END instruction not found END instruction not found
4140 -
Wrong ladder program Position and number of PART
instruction are wrong.
4150
Wrong use of GSTR, GOUT commands GSTR and GOUT is not used
together.
XXX Line No.
4220 -
Excess TMR/CNT or arithmetic instruc-
tions
More than 100 TMR, CNT or
arithmetic instruction used
4230 - Syntax error in TMR/CNT instructions

Table of Contents

Other manuals for YASKAWA NX100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA NX100 and is the answer not in the manual?

YASKAWA NX100 Specifications

General IconGeneral
ManufacturerYASKAWA
ModelNX100
Operating Temperature0 to 45°C
Humidity20 to 80% RH (non-condensing)
Communication InterfacesEthernet
Safety StandardsISO 10218-1
Power Supply200-230V AC, 50/60Hz
Storage Temperature60°C

Related product manuals