8.3 Alarm Message List
8-107
4625
WRONG
EXECUTION OF
LOADDB INST
An error occurred when executing a
LOADDB instruction.
• Reset the alarm, and then try again.
If the error occurs again, contact your
Yaskawa representative.
1 • No file
2 • No directory
4 • There was no directory entry after
this point.
-1 • No file name
-2 • File presence error
-3 • Incorrect file name
-4 • The disk is full.
-5 • The directory is full.
-6 • I/O error
-7 • Invalid handle
-8 • Handle overflow
-9 • File has already been opened.
-10 • File attribute error
-11 • Open mode error
-12 • The hardware disk with large
capacity is used.
-14 • The door is open.
-15 • The disk is write-protected.
-30 • Card controller access error
-31 • No card
-32 • Card drive information readout
error
-33 • Partition table error
-34 • No drive number
-35 • No specified partition number
-36 • Cluster size error
-37 • Incorrect number of sectors
-38 • Sector/byte error
-40 • Card not applicable for I/O
-41 • Nonsupported version
-42 • The setting register did not exist.
-43 • Card not applicable for ATA
-44 • Double chain error
-45 • Media error (not fixed disk)
-50 • Media error (not fixed disk)
4625
WRONG
EXECUTION OF
LOADDB INST
An error occurred when executing a
LOADDB instruction.
• Reset the alarm, and then try again.
If the error occurs again, contact your
Yaskawa representative.
-51 • Sector read command error
-52 • Sector write command error
4626 IMPOSSIBLE S-
AXIS MOV
(IN SPHERE)
--- An error occurred at S-axis high-
speed rotation.
• The S-axis rotation radius was
below the lower limit.
Correct the limit distance for S-axis rotation
center motion (S1CG067).
4627 GUN RECOGNI-
TION SINGLE
OFF
--- The gun identification signal was
not received. (Subcode: Gun num-
ber)
Check the gun identification signal.
Alarm Message List
Alarm
Number
Message
Sub
Code
Cause Remedy