10.1 List of Parameters
10-19
Pn510
2 Output Signal Selection 3 0000 to 0333 0000 After restart Setup
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Reference
Section
Near Signal Mapping (/NEAR)
Reference
Section
0 Disabled (the above signal is not used.)
4.6.7
1 Outputs the signal from CN1-25, -26 output terminal.
2 Outputs the signal from CN1-27, -28 output terminal.
3 Outputs the signal from CN1-29, -30 output terminal.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
