1 - 4 IM 4H3B1-01E
DISPLAY
Left-referenced bargraph: measured data are displayed as a %, on a 0 to 100% scale
Center-zero bargraph: center of the recording span is reference and deviation is displayed as a bargraph
Clock: year/month/day and hours/minutes/seconds
Measured data: AUTO: all channels will be shown alternately
MAN: a specified channel only will be shown
Alarm: channel No., type of alarm (display), channel No. (underneath bargraph, for dot model)
Status indicators: RCD: illuminated when recording is in progress
POC: illuminated when POC is being used (for pen model)
SET: illuminated when in SET Mode
AUTO:illuminated when AUTO display is used
MAN: illuminated when Manual display is used
CLK: illuminated when Clock display is used
ALM: illuminated/flashing when alarm occurs
CHT: illuminated when approx. 2cm are left till chart end (option)
BAT: illuminated/flashing when battery needs to be replaced
CALCULATION
Difference calc (DELT): takes the difference between the measured values of two channels
Linear scaling (SCL): sets different scale (and unit) to a specific range
Square root (SQRT): takes the square root of measured data
MATH: calculates basic arithmetic computations, SQRT, ABS, LOG, EXP, logical and
relational computation (optional)
TLOG: calculates statistic computation for time axis (optional)
COMPUTER INTERFACE (Optional)
RS-422-A
IC MEMORY CARD (Optional)
Storage and retrieval of setting parameters and measured data
REMOTE CONTROL (Optional)
Message printout, manual printout, periodic printout, recording ON/OFF, chart speed
change, TLOG START/STOP, IC memory card trigger.