EasyManua.ls Logo

ZyXEL Communications GS3700 Series - Viewing and Editing Classifier Configuration

ZyXEL Communications GS3700 Series
548 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 19 Classifier
GS3700/XGS3700 Series User’s Guide
206
19.3.1 Viewing and Editing Classifier Configuration
To view a summary of the classifier configuration, scroll down to the summary table at the bottom
of the Classifier screen. To change the settings of a rule, click a number in the I ndex field.
Note: When two rules conflict with each other, a higher layer rule has priority over a lower
layer rule.
Figure 140 Advanced Application > Classifier > Classifier Configuration: Summary Table
The following table describes the labels in this screen.
The following table shows some other common Ethernet types and the corresponding protocol
number.
Add Click this to create a new entry or to update an existing one.
This saves your changes to the Switchs run-time memory. The Switch loses these changes if it
is turned off or loses power, so use the Save link on the top navigation panel to save your
changes to the non-volatile m emory when you are done configuring.
Cancel Click Cancel to begin configuring this screen afresh.
Clear Click Clear to set the above fields back to the factory defaults.
Table 86 Advanced Application > Classifier > Classifier Configuration (continued)
LABEL DESCRIPTION
Table 87 Advanced Application > Classifier > Classifier Configuration: Summary Table
LABEL DESCRIPTION
Index This field displays the index number of the rule. Click an index number to edit the rule.
Active This field displays Yes when the rule is activated and No when it is deactivated.
Weight The field displays the priority of the rule when the match order is in manual mode. A higher
weight means a higher priority.
Name This field displays the descriptive name for this rule. This is for identification purposes only.
Rule This field displays a summary of the classifier rule’s settings.
Select an entry’s check box to select a specific entry. Otherwise, select the check box in the table
heading row to select all entries.
Delete Click Delete to remove the selected entry from the summary table.
Cancel Click Cancel to clear the check boxes.
Table 88 Common Ethernet Types and Protocol Number
ETHERNET TYPE PROTOCOL NUMBER
IP ETHII 0800
X.75 Internet 0801
NBS Internet 0802
ECMA I nternet 0803
Chaosnet 0804