Chapter 31 Error Disable
GS3700/XGS3700 Series User’s Guide
330
The following table describes the labels in this screen.
31.5 Error-Disable Detect Configuration
Use this screen to have the Switch detect whether the control packets exceed the rate limit
configured for a port and configure the action to take once the limit is exceeded. Click the Click
Here link next to Errdisable Detect link in the Advanced Application > Errdisable screen to
display the screen as shown.
Figure 239 Advanced Application > Errdisable > Errdisable Detect
Table 159 Advanced Application > Errdisable > CPU protection
LABEL DESCRIPTION
Reason Select the type of control packet you want to configure here.
Slot (Stacking
mode)
This field appears only in stacking mode. Click the drop-down list to choose the slot
number of the Switch in a stack.
Port (Standalone
or stacking
mode)
This field displays the port number. In stacking mode, the first box field is the slot ID and
the second field is the port number. * means all ports (on the same Switch).
1/ * Use this row to make the setting the same for all ports. Use this row first and then make
adjustments to each port if necessary.
Note: Changes in this row are copied to all the ports as soon as you make them.
Rate Lim it (pkt/
s)
Enter a number from 0 to 256 to specify how many control packets this port can receive or
transmit per second.
0 m eans no rate limit.
You can configure the action that the Switch takes when the limit is exceeded. See
Section
31.5 on page 330
for detailed information.
Apply Click Apply to save your changes to the Switchs run-time memory. The Switch loses
these changes if it is turned off or loses power, so use the Save link on the top navigation
panel to save your changes to the non-volatile memory when you are done configuring.
Cancel Click Cancel to begin configuring this screen afresh.