Chapter 6 Basic Setting
GS3700/XGS3700 Series User’s Guide
96
Figure 58 Basic Setting > Stacking > Stacking Status > Slot number
The following table describes the labels in this screen.
Table 37 Basic Setting > Stacking > Stacking Status > Slot number
LABEL DESCRIPTION
Slot This field displays the slot ID of the Switch.
Stacking This field displays whether the Switch is active in the stacking system.
Role This field displays whether the stacked Switch is a master or linecard Switch.
Force Master
Mode
This field displays whether the Force Master Mode is enabled or disabled on this Switch. The
Active Force Master Mode forces this Switch to become a m aster Switch. This Switch will
have the highest priority over all other Switch in the stack. If two Switches are set as
masters, they will have the same priority level, but the Switch that has the longest active
run-time will be selected as the master Switch automatically.
Priority This field displays the priority level of the Switch. A higher number represents higher
priority.
Slot ID After
Reboot
This field displays the slot ID of the Switch after a reboot. You can save the slot ID of the
Switch after a reboot by clicking Freeze in the Stacking Configuration screen. See
Section 6.10.3 on page 97
.
Stacking Status This field displays whether the stacked Switch is active or inactive in a stack. I nit means
the slot ID is initialized by the master Switch.
Master Capable This field displays whether the Switch has capacity to become a m aster Switch. Auto
means the stack system master election process will determine if the Switch can be
assigned as a master Switch.
Stacking MAC
Address
This field displays the stacking Switch MAC address.
Stacking
Channel 1
This field displays the status of the port stacking channel 1 of the Switch. It will display up
for active or down for inactive.
Stacking
Channel 2
This field displays the status of the port stacking channel 2 of the Switch. It will display up
for active or down for inactive.
Stacking Up
Time
This field displays the time that the active Switch in a stack has been running.
ZyNOS version
* Running/ Flash
This field displays the ZyNOS firmware that is currently running on the Switch.