R3132 Series Spectrum Analyzer Operation Manual
3.3.15 MKR Key (Marker )
3-53
3.3.15 MKR Key (Marker )
This section describes the menu displayed when the
MKR
key is pressed. This menu allows you to use
the active marker data (such as frequency and level) as the data for some other function. Item(s) in the
MKR menu (1/2) may be different depending on the marker you use (either normal or delta marker).
MKR CF Sets the active marker frequency as the center frequency.
MKR Ref Sets the active marker level as the reference level.
Peak CF Moves the marker to the maximum peak within the search range,
and sets the marker frequency as the center frequency.
Peak Ref Moves the marker to the maximum peak within the search range,
and sets the marker level as the reference level.
MKR Span Sets the frequency difference between the delta and normal mark-
er as the frequency span.
1/2_more Displays the Mkr menu (2/2).
MKR CF Step Sets the marker frequency as the center frequency for the step
size.
MKR CF Step Sets the frequency difference between the delta and normal mark-
er as the step size for the center frequency.
MKR MKR Step Sets the marker frequency as the step size of the marker.
MKR MKR Step Sets the frequency difference between the delta and normal mark-
er as the step size of the marker.
MKR CF Sets the frequency difference between the delta and normal mark-
er as the center frequency.
2/2_more Returns to the Mkr menu (1/2).

Table of Contents