Operational Commands
7210 SAS D, E, K OS Quality of Service Guide Page 335
The actual CIR rate is dependent on the meter’s adaptation-rule parameters and the hardware.
Values 0 — 20000000, max (for 7210 SAS-E)
Values 0 — 4000000, max (for 7210 SAS-D)
pir pir-rate-in-kbps — Defines the administrative PIR rate, in kilobits, for the meter. When this command
is executed, a valid PIR setting must be explicitly defined. When the rate command has not been
executed, the default PIR of max is assumed. When the rate command is executed, a PIR setting is
optional.
Fractional values are not allowed and must be given as a positive integer.
The actual PIR rate is dependent on the meter’s adaptation-rule parameters and the hardware.
Values 0 — 20000000, max (for 7210 SAS-E)
Values 0 — 4000000, max (for 7210 SAS-D)