NTP 161 — Replace an I-211M-K or I-211M-L indoor ONT
NTP 161-8 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Figure NTP 161-4: Fiber cable routing for the I-211M-L indoor ONT within the Just Inside
enclosure
iii Position the I-211M-L indoor ONT within the Just Inside enclosure, as
shown in Figure NTP 161-3.
iv Secure the I-211M-L indoor ONT within the Just Inside enclosure.
5 Connect the ground wire (DLP 147). Optional, as required.
The ground is a range of 1/2 to 5/8 inch strip length with outer jacket aligned with
the outer surface of the enclosure.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Note — Observe the following:
• Do not overtighten the ONT bracket when securing the I-211M-L
indoor ONT to the Just Inside enclosure. The unit can become
skewed and compromise the environmental seal of the ONT mounted
in the outdoor enclosure.
Silence
Alarm
System Status
Battery Power
Replace Battery
Auxillary Power
Battery
Emergency Use
22759
Fiber optic
cable
ONT
mounting
hole