4. Setting the Laser Light Output Schedule
<Note>
If the output count set in "SHOT" is smaller than that set in "SHOT [count]", any
larger output count set in "SHOT [count]" is invalidated.
When the output count set in "SHOT" is larger than that set in "SHOT [count]", the
POWER of the nal set value in "SHOT [count]" is repeated until the output count
reaches the output count set in "SHOT."
For example, supposing that "SHOT" is set to 40, up to 40 shots are also validated
for "SHOT [count]." (Up to 40 of POINT 03 on the above screen) When "SHOT" is
set to 300, the POWER of the nal set value is repeated up to 201 to 300 shots for
"SHOT [count]." (In this case, the 20% energy of POINT 06 is repeated up to 201 to
300 shots.)
3
Enabling the Fade Function
(1) Press the "SEAM" setting button to set it to ON.
The fade-in/out function for seam processing is enabled.
When the fade-in/out function is not used, keep the "SEAM" setting button OFF.
When the laser light output count is set to 9999 by using the "SHOT" setting but-
ton, a laser light is continuously output until the laser stop signal is input and the
fade-in/out function becomes disabled.