1. Installation Place
43
ML-5120A
Chapter 1 Installation
Introduction Part
Installation and
Preparation Part
Operating Part Maintenance Part Appendixes
Chapter 1
Installation
This chapter explains where to install the laser equipment, and how to x it.
At installation of this laser equipment, our engineer will take charge of adjust-
ments. Accordingly, this Operation Manual does not describe the adjusting meth-
od at a startup. When the laser is transferred to another installation place, it may
be necessary for our engineer to perform inspection and re-adjustments.
1. Installation Place
The space required for installing the laser equipment and the environment suit-
able for the installation are explained below.
Install laser equipment in a sure place at a level with the ground surface. If the prod-
uct is operated in inclined or fallen form, a failure will occur.
For the power supply side, we earnestly recommend using a leakage breaker
with the rated current of 10 A or more, which is applicable to harmonics and surg-
es.
Perform class D grounding work (Ministry of Economy, Trade and Industry "Tech-
nical Standards for Electric Equipment").