166
ML-5120A
4. Commands
Data No.
Item Data Range
10 [POINT 20] SHOT on the [SEAM] screen 0000 − 9999
78 SEAM setting value POWER 01 to 10
Data No.
Item Data Range
01 [POINT 01] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
02 [POINT 02] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
03 [POINT 03] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
04 [POINT 04] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
05 [POINT 05] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
06 [POINT 06] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
07
[POINT 07] POWER on the [SEAM] screen
0000 − 1500 (×0.1%)
08 [POINT 08] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
09
[POINT 09] POWER on the [SEAM] screen
0000 − 1500 (×0.1%)
10 [POINT 10] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
79 SEAM setting value POWER 11 to 20
Data No.
Item Data Range
01 [POINT 11] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
02 [POINT 12] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
03 [POINT 13] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
04 [POINT 14] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
05 [POINT 15] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
06 [POINT 16] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
07 [POINT 17] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
08 [POINT 18] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
09 [POINT 19] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
10 [POINT 20] POWER on the [SEAM] screen 0000 − 1500 (×0.1%)
64 Modulation Function ON/OFF
Data No.
Item Data Range
01
[MODU] on the [MODULATION] screen
Modulation function ON/OFF 0: OFF 1: ON
0 − 1
65 Modulation Function Settings
Data No.
Item Data Range
01
[WAVE] on the [MODULATION] screen
Selection of modulated waveform
0: Rectangular wave 1: Triangular wave
2: Sinusoidal wave
0 − 2