Section 7 Sample Programs
7-34
11 Call ibwrt(Ans%, "MEAS ADJ,HIGH")'
Moves to adjacent channel leakage power
measurement (High Speed method) screen.
12 Call ibwrt(Ans%, "STORAGE NRM")'
Sets the normal mode.
13 Call ibwrt(Ans%, "ADJRNG")'
Optimizes measurement range.
14 '
15 Call ibwrt(Ans%, "SWP")'
Starts measurement.
16 '
17 Call ibwrt(Ans%, "MODPWR? LOW9Ø,DBM")'
Inquires about measurement rsults of
lowerside next-to-next adjacent channel
leakage power.
18 Low9Ø$ = ReceiveResp()
19 Call ibwrt(Ans%, "MODPWR? LOW6Ø,DBM")'
Inquiries about measurement results of
lowerside next adjacent channel leakage
power.
2Ø Low6Ø$ = ReceiveResp()
21 Call ibwrt(Ans%, "MODPWR? LOW3Ø,DBM")'
Inquiries about measurement results of
lowerside adjacent channel leakage power.
22 Low3Ø$ = ReceiveResp()
23 Call ibwrt(Ans%, "MODPWR? UP3Ø,DBM")'
Inquires about measurement results of
upperside adjacent channel leakage power.
24 Up3Ø$ = ReceiveResp()
25 Call ibwrt(Ans%, "MODPWR? UP6Ø,DBM")'
Inquires about measurement results of
upperside next adjacent channel leakage
power.
26 Up6Ø$ = ReceiveResp()
27 Call ibwrt(Ans%, "MODPWR? UP9Ø,DBM")'
Inquires about measurement results of
upperside next-to-next adjacent channel
leakage power.
28 Up9Ø$ = ReceiveResp()
29 '
3Ø Form212.Print "Adjacent channel power"