Section 7 Sample Programs
7-40
51 '
52 Call ibwrt(Ans%, "AOUT2 OFF")'
Sets AF oscillator (for microphone input
use) to Off.
53 Call ibwrt(Ans%, "RRLVL OFF")'
Sets RF output to Off.
54 End Sub
Set the analog TX measurement with signal generator screen in line 11.
Set the SAT modulation signals of 6 kHz in lines 12 to 16.
Set the AF oscillators for microphone input in lines 18 to 22.
Set the measurement conditions in lines 24 and 25.
Optimize the range in line 28.
Start the measurement in line 29. The SWP command stops accepting the next com-
mand until the measurement terminates.
Read the measurement results in lines 32 to 43.
Set the AF output and RF output to off in lines 52 and 53.