SmartROC D65 T4F 10 Options
138 No: 713944459.6 en
Operator's panel - Semi-automatic fire fighting system
1) Triggering push button: Hold in for 1 second.
2) Flashing light: Fire alarm.
3) Yellow diode on: Fault in trigger loop, gas gener-
ator activated, cable break.
4) Yellow diode on: Fault in detector loop, terminal
resistor missing, cable break.
5) Yellow diode on: Manual mode - System blocked/
semi-automatic.
6) Green diode on: System engaged. Green diode
off: Fault in power supply - Battery fault, cable
break.
7) Button for alarm test and reset: Hold in for at least
1 second. The diodes light up in sequence and
conclude with an alarm test of the signal and
lamp.
In case of fire (Semi-automatic fire fighting system)
1.
Stop the machine's engine.
2.
Trigger the extinguishing system, either electrically with the operator's panel in the
cabin or manually on the outside of the machine.
3.
Move quickly to a safe distance.