SmartROC D65 T4F 6 Operating
69 No: 713944459.6 en
6.8.2 Automatic regeneration
When automatic regeneration is started the symbol high exhaust temperature (A) is
shown in the display.
Time remaining until automatic regeneration
Number of hours remaining until the next automatic regeneration is shown in the display
(B) .
!
NOTE: The number of hours indicated until the next automatic regeneration (B) is only
an approximation. The regeneration process can be started several hours before or
after the time shown.
When automatic regeneration is started the symbol high exhaust temperature (A) is
shown in the display.
Low speed regeneration
Low speed regeneration (LSR) is allowed to start automatically when the engine speed is
between 1200 - 1400 rpm. Other conditions are that the coolant temperature must exceed
+40 °C and the particulate filter's soot content has reached 80-100%.
High speed regeneration
High speed regeneration (HSR) is allowed to start automatically when the engine speed is
between 1200 - 1800 rpm. Other conditions are that the coolant temperature must exceed
+40 °C and the particulate filter's soot content has reached 80-100.