SmartROC D65 T4F 10 Options
200 No: 713944459.6 en
a.
The time can be adjusted via a potentiometer on the inside of the control box.
Remove the 4 screws holding the front panel in place on the control box (A). The
potentiometer is on the left-hand side of the control box. Use a screwdriver to set
the desired time. This screw cleaning period should be established before taking
the first sample.
Potentiometers
1 Potentiometer - use a screwdriver to
set the desired time of the cleaning
procedure
3.
When the screw cleaning procedure is complete, the sampling process starts. To en-
sure that the desired amount of cuttings is collected in the sample holder, adjust the
time with the "Loaded Time" pressure gauge. (6)
4.
After taking a sample of cuttings, the process will pause for the amount of time indic-
ated on the "Break-Time" pressure gauge (7). Ensure that this interval is sufficiently
long enough to empty and replace the sample holder before the next sampling pro-
cedure starts.
5.
The sampler continues working until the stop button is pressed.
10.13 Consumables Logging Function
10.13.1 General
Consumables is an option for SmartROC D65 and SmartROC D60. The Consumables
option helps the driver keep control of the condition of:
n Drill bit
n Drill hammers
n Drill rods
The operator enters a list of consumables in the machine's RCS. The system keeps track
of and displays now many drilled metres each consumable has done. The operator can
then evaluate the performance and ensure a more even wear of the consumables.