SmartROC D65 T4F 8 Drilling
105 No: 713944459.6 en
8.1.5 Direct selection menu F2.
Direct selection menu F2. Settings 1
Quick Settings
In F2 a choice can be made between Settings 1 (see illustration above) and Settings 2
(see next illustration).
n Automatic close of drill support: Automatic close of drill support can be set here so
that the function can be disengaged for single-rod drilling.
n Final air blow before removal: Activates extra flushing when the hole is finished.
n Half rod flushing: Activates extra flushing when a half rod length is drilled.
n Extra flushing: Activates extra flushing before auto drilling.
n Cleaning: Before auto drilling, extra flushing and feed up and down for one drill pipe
length are activated.
n Automatic rod extraction: Select from three functions. Off = Normal extraction. Ro-
tation = Extraction with rotation on. Rotation and air = Extraction with both rotation
and air on.
n Hole Length/Depth: Selection of method of measurement.
n Activate HECL-Pump Manually: The HECL pump can be activated manually from
here and will remain active during an adjustable period of 1-90 minutes, after which the
pump must be reactivated for additional time.
n Ignore Chair Switch
Activated when the positioning levers need to be used when the operator is not seated, for
example, to get a better view through the rear window.
n Emergency mode, Length Sensor: Used if the length sensor has stopped working.
None of the pre-programmed stops will work but the rig can be used until the length
sensor has been rectified. Use rapid feed with great care as none of the stops are
working.