SmartROC D65 T4F 10 Options
139 No: 713944459.6 en
DANGER
Serious injury or death
A fire can re-ignite. Do not return to the machine until you are sure the fire is completely
extinguished.
10.1.2 Manual fire suppression system
Safety
DANGER
Serious injury or death
The fire fighting system's fuel gas cylinders must not be removed by unauthorised ser-
vice personnel. The cylinders are pressurised at 145 bar, which can be lethal if handled
incorrectly.
DANGER
Serious injury or death
The fire fighting system's gas generators contain a small charge and can cause serious
injury. They must not be handled by unauthorised personnel. A gas generator must not
disposed of in normal waste but shall be handled as hazardous goods and sent for de-
struction.
System description
The manual fire fighting system comprises an extinguishing system only. In case of fire,
trigger manually with the device outside the machine.
In case of fire (Manual fire fighting system)
1.
Stop the machine's engine.
2.
Trigger the extinguishing system with the device outside the machine.
3.
Move quickly to a safe distance.
10.1.3 After a fire
The alarm on a semi-automatic system will cease once the fire has been extinguished and
the detectors are cool.
With a manual system, you must perform a visual check from a safe distance to establish
whether the fire is extinguished.