SmartROC D65 T4F 10 Options
155 No: 713944459.6 en
Fig. 10 - Return connection with filler nipple
10.4.3 Safety instructions
Suitable usage
n Use pump 203 only to provide lubricant to the central lubrication system. The pump is
designed for intermittent usage.
General safety instructions
n LINCOLN-QUICKLUB central lubricating system:
- Mounted for reliable usage
n Incorrect usage can result in bearing damage caused by too little or too much lubric-
ant.
n No modifications or changes to the installed system may be made by unauthorised
personnel. All modifications must be preceded by consultation with the manufacturer
or a representative thereof.
Directions for preventing accidents
n Adhere to the instructions for avoiding accidents that apply to the country in which the
pump is used.
Usage, Maintenance and Repair
n Repairs must only be carried out by authorised personnel who are well acquainted with
the instructions.
n LINCOLN-QUICKLUB central lubrication pump may only be in operation with the
safety valve installed.
n LINCOLN-QUICKLUB central lubrication pump must be regularly filled with clean lub-
ricant.
n LINCOLN-QUICKLUB central lubrication system works automatically. Regular checks
must be performed, however, (about every other week) to ensure that the lubricant
reaches all lubrication points.
n A defective circuit board must be packed in a suitable manner and returned to the fact-
ory or local representative.
n Used or dirty lubricant must be disposed of in a legal manner.