SmartROC D65 T4F 10 Options
201 No: 713944459.6 en
10.13.2 Use of Consumables function
Precondition
p
Information on all drill bits, drill hammers and drill rods already imported into the system.
1.
Open the Consumables menu by selecting Logging in the System menu and then
Consumables.
2.
Check which drill bit, drill hammer and drill rod are used at present. Change in the list
if necessary.
a.
Recalibrate the system if changes have been made to the drill rod position.
3.
Start drilling. The Consumables function logs how much each drill bit, drill hammer
and drill rod have drilled during use. This is updated for every ten centimetres drilled.