SmartROC D65 T4F 10 Options
156 No: 713944459.6 en
n The manufacturer of the lubricating system does not accept responsibility for:
- Damage caused by lubricant not intended for pumping or that can only be pumped under
certain conditions in a central lubrication system
- Damage caused by faulty lubrication and insufficient pump filling.
- Damage caused by the use of contaminated lubricant.
- Damaged caused by faulty disposal of used or contaminated lubricant.
10.4.4 Timer 236438624 with adjustable interval time
Power Supply
n The timer receives power through the ignition lock (contact 15) and ground (contact
-31)
n The vehicle operating time and the lubrication system interval time are started and
stopped via the ignition switch
n The system will retain the time settings after turning off the ignition.
10.4.5 Interval time - propagation time
Setting time interval
Range Interval
Hours 1 to 15 hours
Table26: Interval time
Range Interval
Minutes 2 to 30 minutes
Table27: Propagation time
Adjusting interval time/propagation time