SmartROC D65 T4F 6 Operating
60 No: 713944459.6 en
Check point Inspection Instructions
Engine oil Oil level Top up as necessary.
Compressor oil Oil level Before checking the level, make
sure the drill rig is standing level
with the engine turned off for at
least 10 minutes.
Top up as necessary.
Water separator Fuel prefilter Drain off the water (a).
Drill rig. Visual check Look for any signs of leaks,
damage, breakage or cracks.
Table17: Checks before starting.
6.2 Functionality test after start
6.2.1 Checks
!
NOTE: The emergency stop buttons and wires must be checked before each shift and
after tramming.
Check point Inspection Instructions
Emergency stop buttons (all) and
the emergency stop wire on the
feed beam.
Function Check each emergency stop
button individually. The engine
must stop!
Between testing each emer-
gency stop, the previous stop
must be reset before restarting
the rig. For the location of the
stops, see "Safety"
Display for engine and directional
instruments
Visual check Check that none of the fault in-
dicator symbols is on. If a fault is
indicated in the status bar, stop
the unit and rectify the fault.
Table18: Checks.
6.3 Function test while drilling
6.3.1 Checks
Check point Inspection Instructions
Hydraulic hoses to the unit Visual check Check for leaks.