SIP User's Manual 112 Document #: LTRT-65412
MP-11x & MP-124
4. From the 'Profile Preference' drop-down list, select the priority of the IP Profile, where
'1' is the lowest priority and '20' is the highest. If both IP and Tel profiles apply to the
same call, the coders and other common parameters (noted by an asterisk) of the
preferred Profile are applied to that call. If the Preference of the Tel and IP Profiles is
identical, the Tel Profile parameters are applied.
Note:
5. Configure the IP Profile's parameters according to your requirements. Parameters that
are unique to IP Profile are described in the table below.
If the coder lists of both IP and Tel Profiles apply to the same call, only the
coders common to both are used. The order of the coders is determined by the
preference.
6. From the 'Coder Group' drop-down list, select the coder group that you want to assign
to the IP Profile. You can select the device's default coders (refer to ''Configuring
Coders'' 105 on page ), or one of the coder groups you defined in the 'Coder Group
Settings' page (refer to ''Configuring Coder Groups'' 107 on page ).
7. Repeat steps 2 through 6 for the next IP Profiles (optional).
8. Click the Submit
9. To save the changes to flash memory, refer to ''
button to save your changes.
Saving Configuration'' 167 on page .
Table 3-19: Description of Parameter Unique to IP Profile
Parameter Description
Number of Calls Limit Maximum number of concurrent calls. If the profile is set to some limit, the
device maintains the number of concurrent calls (incoming and outgoing)
pertaining to the specific profile. A limit value of '-1' indicates that there is
no limitation on calls for that specific profile (default). A limit value of '0'
indicates that all calls are rejected. When the number of concurrent calls is
equal to the limit, the device rejects any new incoming and outgoing calls
belonging to that profile.
3.3.4.5 SIP Advanced Parameters
The SIP Advanced Parameters submenu allows you to configure advanced SIP control
protocol parameters. This submenu contains the following page items:
Advanced Parameters (refer to ''Configuring Advanced Parameters'' 112 on page )
Supplementary Services (refer to ''Configuring Supplementary Services'' 114 on page )
Metering Tones (refer to “Configuring Metering Tones” on page 116)
Charge Codes (refer to “Configuring the Charge Codes Table” on page 116)
Keypad Features (refer to “Configuring Keypad Features” on page 118)
3.3.4.5.1 Configuring Advanced Parameters
The 'Advanced Parameters' page allows you to configure advanced SIP control
parameters. For a description of the parameters appearing on this page, refer to
Configuration Parameters Reference” on page 213.

Table of Contents