Version 5.8 235 September 2009
SIP User's Manual 6. Configuration Parameters Reference
Parameter Description
Activity Types to Report
via Activity Log Messages
The Activity Log mechanism enables the device to send log messages
(to a Syslog server) for reporting certain types of Web operations
according to the below user-defined filters.
[ActivityListToLog]
[PVC]
Parameters Value Change = Changes made on-the-fly to
parameters.
[AFL]
Auxiliary Files Loading = Loading of auxiliary files (e.g., via
'Certificate' page).
[DR]
Device Reset = Reset of device via the 'Maintenance Actions'
page.
[FB]
Flash Memory Burning = Burning of files or parameters to flash
(in 'Maintenance Actions' page).
[SWU]
Device Software Update = cmp file loading via the Software
Upgrade Wizard.
[ARD]
(1) ini parameters (AdminPage)
Access to Restricted Domains = Access to restricted domains,
which include the following Web pages:
(2) 'General Security Settings'
(5) 'Software Upgrade Key'
(6) 'Internal Firewall'
(N/A)
(8) 'Web User Accounts'
[NAA]
Non Authorized Access = Attempt to access the Web interface
with a false or empty user name or password.
[SPC]
(1) IP Address
Sensitive Parameters Value Change = Changes made to
sensitive parameters:
(3) Default Gateway IP Address
(4) ActivityListToLog
For example: ActivityListToLog = 'pvc', 'afl', 'dr', 'fb', 'swu', 'ard', 'naa',
'spc'
6.3.3 Heartbeat Packet Parameters
The Heartbeat packet parameters are described in the table below. The device sends a
heartbeat packet to ensure that the far-end is passing traffic.
Table 6-16: Heartbeat Packet Parameters
Parameter Description
EMS: APS IP Address Destination IP address (in dotted format notation) to which the device
sends proprietary UDP 'ping' packets.
The default IP address is 0.0.0.0.
[HeartBeatDestIP]
Note:
For this parameter to take effect, a device reset is required.