5.4 Configuring Basic SIP Parameters
This section describes how to configure the device with basic SIP control protocol
parameters using the EMS.
To configure basic SIP parameters:
1. In the MG Tree, select the device that you want to configure.
2. On the Tab bar, click Protocol Definition
Figure 5-3: SIP Protocol Definitions Frame
; the 'SIP Protocol Definitions' frame
appears.
3. Select the Coders
a. Click the
tab; the Coders screen is displayed.
button to add a new Coder entry, and then click Yes
b. Double-click each field to enter values.
to confirm.
c. Right-click the new entry, and then choose Unlock Rows
4. Select the
.
Proxy Server
a. Set 'Proxy Used' to Yes.
tab.
b. (Optional) In the 'Proxy Name' field, enter the Proxy's name. The Proxy name
replaces the Proxy IP address in all SIP messages. This means that messages
are still sent to the physical Proxy IP address, but the SIP URI contains the Proxy
name instead. When no Proxy is used, the internal routing table is used to route
the calls.
c. Click the
button, and then click Yes
d. Enter the IP address of the Proxy Server.
to confirm.
e. Right-click the new entry, and then choose Unlock Rows.