SIP User's Manual 206 Document #: LTRT-65412
MP-11x & MP-124
Possible values for AuthProtocol:
0 none
1 - MD5
2 - SHA-1
Possible values for PrivProtocol:
0 none
1 DES
3 - AES128
5. To end the PuTTY configuration session, type a full-stop (“.”) on an empty line; the
device responds with the following:
INI File replaced
6. To save the configuration to the non-volatile memory, type sar
; the device reboots with
IPSec enabled.
5.8.2 Configuring EMS to Operate with a Pre-configured SNMPv3
System
The procedure below describes how to configure the device with a pre-configured SNMPv3.
To configure the EMS to operate with a pre-configured SNMPv3 system:
1. In the MG Tree, expand the Region to which the device belongs; the MGs (devices)
added to the Region appear.
2. Right-click the device, and then from the shortcut menu, choose Details
Figure 5-7: MG Information Screen
; the 'MG
Information' screen appears.
3. Select the SNMPv3
4. Click
option, and then configure the SNMP fields.
OK
5. Open the 'SNMPv3 Users' screen (
.
Network Provisioning frame > SNMPv3 Users
tab).