Connecting to the Customers Network
October 2002
3 Connect one end of each DW8 cable to each 259A connector.
4 Install a cable from the media gateway to the network through a hub or 110 (purple) wall
field as required.
Cable Connection for C-LAN
Install the circuit packs
!
CAUTION:
When adding or replacing any hardware, be sure to ground yourself against electrostatic
discharge (ESD) by wearing a grounded wrist strap.
Figure notes
1 259A Adapter
2 CAT3/5 Cable with DW8 Connectors
3 To Network
TN799DP Pinout
Backplane Pin 25-Pair Wire Color Lead Name
Peripheral
Connector Pin
103 White/Orange TD+ 27
003 Orange/White TD- 2
104 White/Green RD+ 28
004 Green/White RD- 3
cadlclan KLC 031802
3